🏊 Poolex Vertigo Fi 300T Full Inverter Vertical ASHP with WiFi & Cloud Ready – 37.4kW & R32 (Three Phase)
Premium Full Inverter Swimming Pool Heat Pump | Ultra-Quiet Operation | WiFi Remote Control | Perfect for Large Pools
Transform your swimming experience with the Poolex Vertigo Fi 300T – a cutting-edge, full inverter heat pump designed for serious pool owners who demand exceptional performance, whisper-quiet operation, and intelligent control. With an impressive 37.4kW heating capacity and revolutionary vertical design, this heat pump delivers professional-grade pool heating while saving space and energy costs.
Why Choose the Poolex Vertigo Fi 300T? 🌟
The Vertigo Fi 300T represents the pinnacle of swimming pool heating technology. Unlike conventional on/off heat pumps that waste energy and create noise spikes, this full inverter model continuously adjusts its power output to match your pool’s exact heating needs. The result? Up to 80% energy savings compared to traditional heating systems, ultra-quiet operation as low as 30dBA at 10 meters, and faster, more consistent pool heating.
Perfect for:
- Large residential swimming pools (170-210m³)
- Commercial pool installations
- Year-round pool heating requirements
- Noise-sensitive locations
- Pools in confined spaces requiring vertical discharge
- Owners seeking smart home integration
🎯 Key Features & Benefits
🔥 Exceptional Heating Power
With 37.4kW heating capacity at optimal conditions (A26/W26), the Vertigo Fi 300T can heat pools up to 210m³ efficiently. The advanced full inverter technology delivers precise temperature control while maintaining industry-leading energy efficiency with a COP up to 15.36 – meaning you get over 15kW of heating for every 1kW of electricity consumed.
🤫 Whisper-Quiet Operation
Experience virtually silent pool heating with noise levels as low as 30dBA at 10 meters – quieter than a whisper! The Silent Mode reduces sound pressure even further, making this ideal for residential areas where noise restrictions apply. Multiple operating modes let you prioritize either speed or silence based on your needs.
📱 Smart WiFi Control
Take complete control from anywhere using the Poolex smartphone app (iOS & Android). Monitor your pool temperature in real-time, adjust settings remotely, switch between heating and cooling modes, and create custom schedules – all from the palm of your hand. The built-in WiFi connectivity means no additional hardware required.
⬆️ Space-Saving Vertical Design
The innovative vertical architecture with upward air discharge makes the Vertigo Fi 300T perfect for tight installation spaces. Unlike horizontal heat pumps that require large clearance areas, this compact design measures just 660 x 660 x 1030mm while delivering commercial-grade heating power.
🌍 Eco-Friendly R32 Refrigerant
Utilizing the latest R32 refrigerant technology, this heat pump reduces environmental impact by 75% compared to older R410A systems. R32 has zero ozone depletion potential and a significantly lower global warming potential, making it the responsible choice for environmentally conscious pool owners.
💎 Premium Components
- Toshiba Compressor: Renowned for reliability and efficiency
- Titanium Heat Exchanger: Completely resistant to chlorine, salt, and chemical corrosion (15-year warranty)
- DC Inverter Fan & Motor: Variable speed operation for optimal efficiency
- Weather-Resistant ABS Casing: UV-treated, durable housing with integrated LCD display
❄️ All-Season Performance
Operates effectively in ambient temperatures from -10°C to +43°C, with a dual antifreeze system protecting your investment even in harsh winter conditions. Heating range from 15°C to 40°C and optional cooling mode (8°C to 28°C) means year-round comfort.
📄 Downloads & Documentation
📥 Installation & User Manual (opens in new tab)
Complete 44-page installation and operation manual including:
- Detailed installation instructions with diagrams
- Electrical connection specifications for three-phase supply
- Hydraulic connection guidance with bypass kit setup
- WiFi setup and smartphone app pairing instructions
- Operating modes and programming guide
- Maintenance schedules and winterization procedures
- Troubleshooting and error code reference
- Wiring diagrams and technical appendices
This comprehensive manual ensures proper installation and helps you maximize the performance and longevity of your heat pump.
🎮 Intelligent Operating Modes
The Vertigo Fi 300T offers five distinct operating modes, allowing you to optimize performance for any situation:
🔷 Auto Mode The heat pump intelligently selects the most appropriate operating mode based on your set temperature, weather conditions, and pool requirements. Perfect for hands-off operation.
🔷 Inverter Heating Mode (Boost) Maximum heating power for the fastest temperature rise. Ideal when you need to heat your pool quickly or recover temperature after cooler weather.
🔷 Eco Heating Mode Balanced performance and efficiency for conventional day-to-day operation. The heat pump gradually adjusts output to maintain your desired temperature while minimizing electricity consumption.
🔷 Silent Mode Prioritizes whisper-quiet operation while still delivering effective heating. Compressor and fan speeds are reduced to achieve noise levels barely audible from 10 meters away.
🔷 Cooling Mode (Summer Feature) When temperatures soar, switch to cooling mode to lower your pool water temperature for refreshing summer swims. Operates at 8°C to 28°C range.
📊 Technical Specifications
Performance Data
| Specification | Value |
|---|---|
| Maximum Heating Capacity (A26/W26) | 37.4 kW |
| Power Input Range (A26/W26) | 0.51 – 6.03 kW |
| COP at A26/W26 | 6.75 – 15.36 |
| Maximum Heating Capacity (A15/W26) | 29.06 kW |
| Power Input Range (A15/W26) | 0.84 – 5.97 kW |
| COP at A15/W26 | 4.81 – 7.52 |
| Maximum Power Input | 8.2 kW |
| Cooling Capacity (A35/W27) | 19.54 – 6.51 kW |
| Average EER (Cooling) | 4.79 – 3.39 |
Electrical Specifications
| Specification | Value |
|---|---|
| Voltage | 380-415V (Three Phase) |
| Maximum Current | 14.66A |
| Minimum Fuse/MCB | 16A (Type C or D curve recommended) |
| Cable Requirement | RO2V 5×2.5 mm² (up to 10m length) |
| Power Supply Protection | IPX4 rated |
Physical & Operational Specifications
| Specification | Value |
|---|---|
| Dimensions (L x W x H) | 660 x 660 x 1030 mm |
| Weight | 100 kg |
| Noise Level (at 1m) | 49-59 dBA |
| Noise Level (at 10m) | 30-39 dBA |
| Water Connections | 50mm / 1½ inch PVC |
| Nominal Flow Rate | 12.5 m³/h |
| Min/Max Flow Rate | 13.0 m³/h |
| Air Direction | Vertical (upward discharge) |
| Refrigerant Type | R32 (eco-friendly) |
| Compressor Type | Mitsubishi Twin-Rotary |
| Heat Exchanger | Titanium coil (chlorine & salt resistant) |
Operating Temperature Ranges
| Mode | Temperature Range |
|---|---|
| Heating Mode | 15°C – 40°C |
| Cooling Mode | 8°C – 28°C |
| Ambient Operating Range | -10°C – +43°C |
| Antifreeze Activation | Below 2°C (automatic) |
Recommended Pool Coverage
| Pool Type | Volume Range |
|---|---|
| In-Ground Pools (Covered) | 170 – 210 m³ |
| Above-Ground Pools (Covered) | 150 – 190 m³ |
| Uncovered Pools | 120 – 150 m³ |
Note: Pool sizing assumes use of a thermal cover, good insulation, and average UK climate. Actual performance varies based on installation conditions, ambient temperature, desired water temperature, and pool cover usage.
⏱️ Heat-Up Time Estimates
Understanding how quickly your pool will heat is crucial for planning. Below are estimated heat-up times for various pool sizes under optimal conditions (A15/W26). These calculations use the heat pump’s 29.06kW capacity at 15°C ambient temperature.
Formula Used:
Time (hours) = (Pool Volume in m³ × Temperature Rise in °C × 1.16) ÷ Heat Pump kW Rating
🌊 Small to Medium Pools (50-100m³)
| Pool Volume | Temperature Rise | Estimated Time | Daily Heating (with cover) |
|---|---|---|---|
| 50m³ | 5°C | 10.0 hours | 1.2-1.5°C |
| 50m³ | 10°C | 20.0 hours | 1.2-1.5°C |
| 75m³ | 5°C | 14.9 hours | 1.6-2.0°C |
| 75m³ | 10°C | 29.9 hours | 1.6-2.0°C |
| 100m³ | 5°C | 19.9 hours | 1.8-2.2°C |
| 100m³ | 10°C | 39.9 hours | 1.8-2.2°C |
🏊 Large Pools (125-200m³)
| Pool Volume | Temperature Rise | Estimated Time | Daily Heating (with cover) |
|---|---|---|---|
| 125m³ | 5°C | 24.9 hours | 2.0-2.4°C |
| 125m³ | 10°C | 49.8 hours | 2.0-2.4°C |
| 150m³ | 5°C | 29.9 hours | 2.2-2.6°C |
| 150m³ | 10°C | 59.8 hours | 2.2-2.6°C |
| 175m³ | 5°C | 34.9 hours | 2.4-2.8°C |
| 175m³ | 10°C | 69.7 hours | 2.4-2.8°C |
| 200m³ | 5°C | 39.9 hours | 2.6-3.0°C |
| 200m³ | 10°C | 79.7 hours | 2.6-3.0°C |
⚠️ Important Heat-Up Time Considerations:
✅ These are theoretical estimates based on continuous operation and optimal conditions
✅ Actual times vary based on ambient temperature, wind exposure, pool cover usage, and insulation
✅ Use a thermal pool cover to retain heat – up to 80% of heat loss occurs through surface evaporation
✅ Initial heat-up (from cold) takes longer than maintaining temperature
✅ Colder ambient temperatures reduce heating capacity and increase time required
✅ Above-ground pools lose heat faster than in-ground pools – consider additional insulation
✅ Daily heating performance shown assumes use of a pool cover when not in use
💰 Running Cost Comparison
See how the Vertigo Fi 300T compares to alternative heating methods for a typical 150m³ pool:
| Heating Method | Typical Daily Cost | Monthly Cost (May-Sep) | Annual CO₂ Emissions | Efficiency |
|---|---|---|---|---|
| Poolex Vertigo Fi 300T | £3-5 | £90-150 | 400-600 kg | ⭐⭐⭐⭐⭐ |
| Standard Heat Pump | £5-8 | £150-240 | 600-900 kg | ⭐⭐⭐⭐ |
| Gas Boiler | £15-25 | £450-750 | 2,000-3,000 kg | ⭐⭐ |
| Oil Boiler | £18-30 | £540-900 | 2,400-3,600 kg | ⭐⭐ |
| Electric Heater | £25-40 | £750-1,200 | 3,000-4,500 kg | ⭐ |
Based on UK average energy prices: Electricity £0.24/kWh, Gas £0.06/kWh, Oil £0.08/kWh. Assumes covered pool, May-September usage, maintaining 28°C water temperature with 15-18°C average ambient temperature.
💡 Key Savings:
- Save up to £600-£1,050 annually compared to gas heating
- Save up to £900-£1,500 annually compared to electric heating
- Reduce carbon footprint by up to 70-85% versus fossil fuel heating
- Typical payback period: 3-5 years compared to gas, 2-3 years compared to electric
🛠️ Installation Requirements & Guidelines
Electrical Installation ⚡
CRITICAL: Must be installed by a qualified electrician in accordance with current regulations.
Power Supply Requirements:
- Three-phase supply: 380-415V / 50Hz
- Maximum current: 14.66A
- Circuit breaker: 16A Type C or D curve (slow type)
- Cable specification: RO2V 5×2.5 mm² (for cable runs up to 10m)
- Upstream protection: 30mA RCD (differential switch)
- Earth connection: Mandatory
⚠️ Phase Sequence Critical: Three-phase connections must be in correct sequence or the compressor will not operate. Verify phase order before powering on.
Hydraulic Connection 💧
Flow Rate Specifications:
- Nominal flow rate: 12.5 m³/h
- Maximum flow rate: 13.0 m³/h
- Water connections: 50mm (1½ inch) PVC unions included
Bypass Kit Requirements:
- Three-valve bypass assembly mandatory (valves included)
- Allows isolation for maintenance without system shutdown
- Regulates water flow through heat pump
- Prevents excessive flow rate that reduces efficiency
Important Flow Notes: ✅ Filtration pump must provide adequate flow (12.5 m³/h minimum)
✅ Install bypass system for above-ground pools to optimize flow
✅ Position heat pump AFTER filtration, BEFORE chemical treatment systems
✅ Use flexible PVC connections to reduce vibration transmission
✅ Water must flow continuously when heat pump operates
Physical Installation 📐
Clearance Requirements:
| Location | Minimum Clearance |
|---|---|
| Front (air intake) | 500mm (0.5m) |
| Sides | 500mm (0.5m) each side |
| Rear | 500mm (0.5m) |
| Top (vertical discharge) | 2,500mm (2.5m) clear above unit |
Installation Surface:
- Level, stable concrete base required
- Must support 100kg unit weight
- Drainage provision for condensate water
- Optional: Anti-vibration pads included for noise reduction
- Elevate unit 10cm minimum if condensate drainage kit used
Location Considerations: ✅ Well-ventilated area with good air circulation
✅ Avoid direct sun exposure to control panel
✅ Position discharge away from building windows
✅ Avoid recirculation of exhaust air
✅ Keep away from roads (mud splash prevention)
✅ Minimize noise impact on neighbors
✅ Keep out of reach of children
✅ Avoid areas with oil, flammable gases, or corrosive substances
Above-Ground Pool Installation:
- Position heat pump at ground level (below waterline) – elevation unnecessary
- Bypass kit essential for flow optimization and winterization
- Additional pool insulation recommended for efficiency improvement
- May allow smaller heat pump sizing with proper insulation
🎛️ LED Status Indicators
The Vertigo Fi 300T features intuitive LED indicators on the front panel for instant status recognition:
🟢 GREEN LED
Temperature setpoint has been reached. Heat pump in standby mode, maintaining temperature.
🔵 BLUE LED
Pool water is actively being heated. Compressor and fan operating.
🔴 RED LED
Heat pump out of service. Check error code on display or refer to manual for troubleshooting.
LEDs can be disabled via control panel if preferred for nighttime operation.
📦 What’s Included
Your Poolex Vertigo Fi 300T comes complete with everything needed for installation:
✅ Poolex Vertigo Fi 300T Heat Pump Unit
✅ 2 x Hydraulic Connectors (50mm diameter PVC unions)
✅ Condensate Drainage Kit with hose
✅ 4 x Anti-Vibration Rubber Isolating Feet
✅ Winter Protection Cover (custom-fit)
✅ Comprehensive Installation & User Manual (44 pages)
✅ Built-in WiFi Module (no additional hardware required)
Not included: Electrical cable, bypass valves, PVC piping, mounting hardware – these must be purchased separately based on your specific installation requirements.
🛡️ Industry-Leading Warranty
Poolex stands behind the quality and durability of the Vertigo Fi range with exceptional warranty coverage:
🏆 Heat Pump Unit: 5 Years comprehensive warranty
🏆 Compressor: 7 Years (parts only after Year 5)
🏆 Titanium Coil: 15 Years anti-corrosion warranty (parts only after Year 5)
🔧 Maintenance & Winterization
Regular Maintenance (User)
Monthly Tasks:
- Check water flow rate and clean pool filter if necessary
- Verify bypass valves are correctly positioned
- Inspect for any visible damage or loose connections
- Monitor noise levels for any changes indicating issues
Annual Professional Service: Qualified technician must perform:
- Comprehensive safety checks
- Electrical wiring integrity verification
- Earth connection testing
- Pressure gauge monitoring and refrigerant level check
- Component inspection for wear or corrosion
Winter Storage & Protection ❄️
When ambient temperatures drop below 3°C and pool not in use:
Step 1: Disconnect electrical power supply
Step 2: Close inlet and outlet isolation valves
Step 3: Open bypass valve fully
Step 4: Remove drain plug and water pipe connections
Step 5: Allow complete drainage of heat exchanger
Step 6: Replace drain plug (or block with cloth)
Step 7: Install winter protection cover (included)
Automatic Antifreeze Protection: If heat pump remains powered during winter, automatic antifreeze activates when temperatures drop below 2°C. System briefly runs compressor and circulation pump to prevent freezing damage. This feature requires:
- Heat pump electrically connected
- Circulation pump operational (or servo-controlled)
- Sufficient water in system
⚠️ Frost Damage Not Covered by Warranty – Proper winterization or antifreeze protection mandatory in freezing climates.
❓ Frequently Asked Questions
1. What size pool is the Vertigo Fi 300T suitable for?
The Vertigo Fi 300T is designed for large pools between 170-210m³ (approximately 45,000-55,000 gallons) when using a pool cover. For uncovered pools or above-ground installations, we recommend sizing for 120-150m³. Pool size suitability depends on several factors including climate, desired water temperature, pool insulation, and how quickly you want to heat the pool. For personalized sizing advice, consult with a qualified pool heating specialist.
2. How much does it cost to run the Vertigo Fi 300T?
Running costs vary based on climate, pool size, desired temperature, and electricity tariff. For a typical 150m³ pool in the UK maintaining 28°C during swimming season (May-September), expect daily running costs of £3-5, or approximately £90-150 per month. This assumes use of a thermal pool cover and average ambient temperatures of 15-18°C. The full inverter technology can save up to 80% compared to traditional electric heaters and 60-70% versus gas heating.
3. Does this heat pump work in cold weather?
Yes! The Vertigo Fi 300T operates effectively in ambient temperatures from -10°C to +43°C. Heating capacity reduces at lower ambient temperatures (this is normal for all heat pumps), but the unit continues to function. At 15°C ambient temperature, heating capacity is 29.06kW – still substantial performance. The automatic defrost system ensures operation even below freezing, and antifreeze protection prevents damage when temperatures drop below 2°C.
4. Why is three-phase power required?
Three-phase power (380-415V) is necessary to efficiently operate the high-capacity 37.4kW heating system. Three-phase supply distributes electrical load more evenly, reduces current per phase (only 14.66A), and allows use of smaller cable sizes compared to single-phase alternatives. Most commercial properties and larger homes have three-phase power available. If uncertain about your electrical supply, consult a qualified electrician before purchasing.
5. How quiet is this heat pump?
Exceptionally quiet! The Vertigo Fi 300T produces noise levels as low as 30-39dBA at 10 meters distance – quieter than a whisper and barely perceptible. At 1 meter, noise levels range from 49-59dBA (similar to a quiet conversation). The Silent Mode reduces noise even further by limiting compressor and fan speeds. The full inverter technology eliminates the on/off cycling noise associated with conventional heat pumps, providing smooth, continuous, near-silent operation.
6. Can I control the heat pump from my smartphone?
Absolutely! The Vertigo Fi 300T has WiFi connectivity built-in as standard. Download the free “Smart Life” app (iOS or Android), create an account, and pair your heat pump in minutes. The app allows you to:
- Monitor pool temperature in real-time
- Adjust target temperature remotely
- Switch between heating/cooling modes
- Create custom heating schedules
- Turn unit on/off from anywhere
- Receive operational alerts
- View energy consumption data
The app also integrates with Amazon Echo and Google Home for voice control (availability varies by country).
7. How long does it take to heat my pool?
Heat-up time depends on pool volume, starting temperature, desired temperature, and ambient conditions. As a general guide, the Vertigo Fi 300T can heat a covered 150m³ pool by 5°C in approximately 30 hours of continuous operation at 15°C ambient temperature. Daily heating rates of 2.2-2.6°C are typical for this pool size when using a cover. Initial heat-up from cold takes longer than maintaining temperature. See the detailed heat-up tables above for specific pool size calculations.
8. What maintenance is required?
Routine maintenance is minimal:
- Monthly: Check water flow, clean pool filter, verify bypass valve settings
- Annually: Professional service by qualified technician (safety checks, electrical verification, refrigerant level check)
- Seasonally: Winterization if pool not used in freezing temperatures (or ensure antifreeze protection active)
The titanium heat exchanger is completely resistant to chlorine and salt, requiring no special maintenance. Anti-vibration feet and weather-resistant ABS casing ensure long-term durability with minimal intervention.
9. Can this heat pump cool my pool in summer?
Yes! The Vertigo Fi 300T includes cooling mode functionality, allowing you to lower pool water temperature during hot summer periods. Cooling capacity is 19.54kW at optimal conditions (A35/W27), with an impressive Energy Efficiency Ratio (EER) of up to 4.79. This is particularly valuable for hydrotherapy pools, training pools, or regions with very hot summers where excessively warm water is uncomfortable for swimming.
10. What’s the difference between Inverter, Eco, and Silent modes?
- Inverter Mode (Boost): Maximum heating output for fastest temperature rise. Compressor and fan run at variable speeds optimized for power. Use when rapid heating needed.
- Eco Mode: Balanced performance for standard day-to-day operation. Heat pump gradually adjusts output to maintain temperature efficiently. Best for general use and overnight operation.
- Silent Mode: Prioritizes low noise operation while still heating effectively. Compressor and fan speeds reduced. Perfect for noise-sensitive areas or evening/nighttime use.
- Auto Mode: Heat pump intelligently selects the most appropriate mode based on temperature differential and conditions. Set your desired temperature and let the system optimize.
All modes utilize full inverter technology for superior efficiency versus conventional on/off heat pumps.
11. Is a pool cover really necessary?
While not absolutely required, a thermal pool cover is highly recommended and dramatically improves efficiency. Up to 80% of pool heat loss occurs through surface evaporation. A cover can:
- Reduce heat loss by 70-90%
- Cut running costs by 50-70%
- Allow smaller heat pump sizing
- Speed up initial heat-up time
- Maintain temperature overnight without continuous operation
- Reduce chemical consumption and debris
For above-ground pools especially, combining a cover with additional sidewall insulation can reduce required heat pump size and substantially lower operating costs.
12. What chemicals can be used with this heat pump?
The Vertigo Fi 300T is compatible with all standard pool treatment systems including:
- Chlorine (liquid, tablet, or granular)
- Bromine
- Salt water chlorination systems
- pH adjustment chemicals
- Ozone systems
Important: All chemical treatment systems (dosing pumps, salt chlorinators) MUST be installed AFTER the heat pump in the hydraulic circuit to prevent corrosion. Maintain water pH between 6.9-8.0 at all times. The titanium heat exchanger is highly resistant to chemical corrosion, but proper water chemistry is still essential for longevity.
🚚 Delivery & Installation
Product Weight: 100kg
Packaging Dimensions: Approximately 760 x 760 x 1150mm
Delivery: Unit ships on pallet in original protective packaging
Installation Requirements:
- Qualified electrician (mandatory for electrical connection)
- Plumber or pool professional (recommended for hydraulic connection)
- Two-person lifting team (unit weight 100kg)
Installation Time: Typically 4-6 hours for complete installation including electrical, hydraulic, and commissioning by experienced professionals.
💡 Expert Tips for Maximum Efficiency
🔹 Optimize Bypass Settings
Correctly adjusted bypass valves ensure optimal water flow rate (12.5 m³/h). Too much flow reduces heat transfer efficiency; too little can trigger low-flow errors.
🔹 Use Night Setback
Program lower target temperatures overnight (2-3°C lower). The pool retains heat well when covered, and you’ll save electricity during peak rate periods.
🔹 Position Strategically
Install in area with good air circulation. The heat pump extracts heat from ambient air – better airflow = better efficiency.
🔹 Extend Swimming Season
With the Vertigo Fi 300T’s low-temperature operation capability, you can comfortably swim from April through October in the UK, potentially longer in milder regions.
🔹 Monitor Filter Cleanliness
Clean pool filter regularly. Restricted water flow reduces heat pump efficiency and can trigger protection errors.
🔹 Combine with Solar
Pairing this heat pump with solar pool heating provides the best of both worlds: free solar heating on sunny days, reliable heat pump backup for cloudy/cool periods.
🏅 Why Buy from Parts4Tubs?
✅ Authorized Poolex Dealer – Genuine products with full manufacturer warranty
✅ Expert Technical Support – Knowledgeable team available for installation advice
✅ Competitive Pricing – Best value on premium pool heating equipment
✅ Fast UK Delivery – Quick dispatch from UK warehouse
✅ Professional Installation Network – Can recommend qualified installers in your area
⚠️ Important Safety Information
DANGER – FLAMMABLE REFRIGERANT R32
This heat pump contains R32 refrigerant which is classified as mildly flammable (A2L). While R32 is significantly safer than older flammable refrigerants and poses minimal risk during normal operation, the following safety requirements MUST be observed:
🔴 Installation and service must only be performed by qualified, certified refrigeration technicians
🔴 Any work on refrigerant circuit absolutely prohibited without valid authorization
🔴 No smoking, open flames, or ignition sources near unit during installation or service
🔴 Adequate ventilation required during installation and maintenance
🔴 Fire extinguisher (dry powder or CO₂) must be available during any hot work
🔴 Never use oxygen or compressed air for leak testing – use nitrogen only
Electrical Safety: ⚡ Disconnect power supply before any maintenance or cleaning
⚡ Earth connection mandatory
⚡ RCD protection required (30mA)
⚡ Never touch fan when unit operating
⚡ Keep children away from unit at all times
Operational Safety: ❌ Never operate without water circulating
❌ Never block air intake or discharge
❌ Do not insert objects into air or water openings
❌ Maintain proper water chemistry (pH 6.9-8.0)
📋 Summary – Is the Vertigo Fi 300T Right for You?
Choose the Poolex Vertigo Fi 300T if you have:
✅ A large swimming pool (170-210m³) requiring powerful, efficient heating
✅ Three-phase electrical supply available
✅ Limited installation space requiring compact, vertical-discharge design
✅ Noise-sensitive location where ultra-quiet operation essential
✅ Desire for smart home integration with WiFi control
✅ Commitment to environmental responsibility (eco-friendly R32)
✅ Year-round or extended season swimming aspirations
✅ Budget for premium equipment with exceptional warranty coverage
Consider alternatives if:
❌ Pool smaller than 150m³ (consider lower kW models: Vertigo Fi 200T or 240T)
❌ Only single-phase electrical supply available (single-phase models available)
❌ Budget is primary concern over features (conventional heat pumps available)
❌ Immediate heating required daily (solar may be more suitable supplementary option)
🛒 Ready to Transform Your Pool Experience?
The Poolex Vertigo Fi 300T represents the ultimate in swimming pool heating technology – combining cutting-edge full inverter efficiency, whisper-quiet operation, intelligent WiFi control, and the space-saving convenience of vertical design. With exceptional heating power, industry-leading warranty coverage, and the eco-friendly R32 refrigerant, this is the heat pump serious pool owners choose.
Don’t let another swimming season pass with a cold pool. Invest in year-round comfort, dramatic energy savings, and effortless smart control.
Poolex is a premium brand of Poolstar Group. The Vertigo Fi range represents over 20 years of research and development in pool heating technology, delivering unmatched performance, efficiency, and reliability.