⚡ Certikin iSAVER-X Pool Pump Frequency Inverter
Transform Your Single-Speed Pump into Variable Speed – Control Flow Rates & Run Times with Touch Screen Technology 🎛️
📋 Product Overview
The Certikin iSAVER-X is a frequency inverter designed to reduce the running costs of pool circulation pumps and improve the efficiency of swimming pool filtration. Swimming pool pumps invariably run at higher flow rates than necessary—with an iSAVER-X you can control both pump flow rates and pump run times.
The iSAVER-X features touch screen control and can be used with permanent split capacitor single-phase pool pump motors. The device allows users to set up to 4 timers for daily operation, each with an individual speed setting. The easy-to-read display shows current operational settings including rpm, power consumption, and timer information.
⭐ Key Features
✅ Touch Screen Control Panel – Easy-to-read LCD display with intuitive button controls
✅ 3 Speed Modes – Night (Low), Day (Medium), and Backwash (High) pre-set speed ranges
✅ 4 Programmable Timers – Set different speeds for different times of day
✅ Speed Range 1200–2900 rpm – Adjustable in 50 rpm increments
✅ Power Consumption Display – Real-time wattage shown on screen
✅ Automatic Self-Priming – Runs at 2900 rpm for 1 minute on startup (adjustable to 10 minutes)
✅ Power-Off Memory – Operation state resumes after power restoration
✅ Wall Mounted Installation – Compact design with mounting hardware included
✅ Ventilation & Fan Cooling – Built-in thermal management
✅ CE Approved – European conformity certified
🔧 Technical Specifications
iSAVER-X 1100 (Single-Phase Pump Output)
| Specification | Value |
|---|---|
| Model | iSAVER-X 1100 |
| Input Power | 1 phase AC |
| Input Voltage | 220–240V |
| Input Frequency | 50Hz |
| Output Power | Max 1.1 kW |
| Output Voltage | 1ph, 0–240V |
| Pump Type | Single phase |
| Max Current | 6A |
| Speed Range | 1200–2900 rpm |
| Cooling | Ventilation and Fan cooling |
| Dimensions (L×H×W) | 222 × 117 × 166 mm |
🎚️ Speed Modes
| Mode | Speed Range | Default Speed |
|---|---|---|
| Night (Low) | 1200–1650 rpm | 1400 rpm |
| Day (Medium) | 1700–2400 rpm | 2000 rpm |
| Backwash (High) | 2450–2900 rpm | 2900 rpm |
⚙️ Parameter Settings
| Parameter | Description | Default | Range |
|---|---|---|---|
| 1 | Priming time | 1 minute | 0–10 min (1 min increments) |
| 2 | Minimum RPM | 1200 rpm | 1200–2000 rpm (100 rpm increments) |
| 6 | Self-priming speed | 2900 rpm | 1200–2900 rpm (100 rpm increments) |
⚠️ Compatibility
Compatible with:
- Pool pumps with permanent split capacitor motors (single-phase)
NOT compatible with:
- Single (Three) phase motors with centrifugal switch
- Pool pump motors with start relays or switch
- Series or DC motors
- Pool pump motors with faults in their rotors or capacitors
- Shaded-pole asynchronous motors
Important: If you are not sure of the compatibility of your pool pump with this device, please contact your supplier or manufacturer before proceeding with installation.
🛠️ Installation Requirements
Environmental Conditions:
- Ambient temperature: -10°C to +40°C
- Relative humidity: 45–90% (non-condensing)
- Altitude: Less than 1000m above sea level
- Keep out of direct sunlight
- Good ventilation required
Electrical Requirements:
- An RCD with rated residual current not exceeding 30mA must be used
- Total cable length (device output + pump cable) should not exceed 2m
- Do not use extension leads
Installation Notes:
- Only ONE pump can be connected to the inverter
- Do not connect any other appliance to the output
- Wall mounting hardware supplied
- For iSAVER-X 1100C, connect pump motor with delta connection
🚨 Protection & Error Codes
| Code | Description |
|---|---|
| E001 | Abnormal input voltage |
| E002 | Output over current |
| E101 | Heat sink over heat |
| E102 | Heat sink sensor error |
| E103 | Master driver board error |
| E201 | Circuit board error |
| E202 | Master board EEPROM reading failure |
| E203 | RTC time reading error |
| E204 | Keyboard EEPROM reading failure |
| E205 | Communication error |
| AL01 | High-temperature warning and speed reduction |
Note: AL01 is a warning—the inverter will automatically switch to lower speed to self-protect. When temperature drops to 68°C, it resumes preset speed.
📥 Downloads & Resources
📄 Certikin iSAVER-X Brochure – Product overview and features (PDF)
📄 Certikin iSAVER-X Installation & Operation Manual – Complete installation instructions, wiring diagrams, and programming guide (PDF)
🏆 Why Choose Certikin iSAVER-X?
✅ Touch Screen Interface – Modern, easy-to-use control panel
✅ 4 Programmable Timers – Automate pump operation for different times of day
✅ Real-Time Power Display – Monitor energy consumption
✅ Adjustable Speed Control – Fine-tune in 50 rpm increments
✅ Automatic Self-Priming – Protects pump on startup
✅ Built-In Thermal Protection – Automatic speed reduction on overheating
✅ Power-Off Memory – Settings retained during power outages
✅ Compact Design – 222 × 117 × 166 mm wall-mounted unit
✅ CE Approved – European safety certified
🛒 Why Buy From Parts4Tubs?
✅ Authorised Certikin Distributor – Genuine products with manufacturer support
✅ Technical Expertise – Assistance with pump compatibility queries
✅ Competitive UK Pricing – Trade pricing available
✅ Fast UK Delivery – In-stock items dispatched promptly
✅ Installation Support – Help with wiring and setup questions
✨ Summary
The Certikin iSAVER-X Frequency Inverter enables control of pool pump flow rates and run times through touch screen technology. Compatible with permanent split capacitor single-phase motors, it offers 3 speed modes (1200–2900 rpm), 4 programmable timers, real-time power consumption display, and automatic self-priming. The compact 222 × 117 × 166 mm unit features wall mounting, fan cooling, built-in thermal protection, and CE certification. Available in single-phase output (1100) and three-phase output (1100C) versions, both with 1.1 kW maximum output power.