Dantherm CDP70 Professional Wall Mounted Dehumidifier – 69L/Day Commercial Pool System 💧
Transform your indoor pool environment with the Dantherm CDP70, the premium solution for commercial humidity control. This Danish-engineered wall-mounted dehumidifier delivers exceptional performance with 69 litres per day extraction capacity, making it the ideal choice for demanding aquatic environments.
The CDP70 represents the pinnacle of Dantherm’s professional dehumidifier range, specifically designed for commercial swimming pools, spa facilities, and high-traffic aquatic centers. With intelligent defrosting technology, energy-efficient operation, and whisper-quiet performance, this system provides reliable moisture control while minimizing operational costs.
Perfect for:
- 🏊 Commercial swimming pools
- 💆 Large spa and wellness facilities
- 🏨 Hotel and resort pool areas
- 🏋️ Health clubs and fitness centers
- 🏢 Therapy pools and rehabilitation centers
🎯 Key Features & Benefits
Maximum Moisture Control
69 Litres Daily Capacity – The CDP70 extracts up to 69 litres of moisture per day (at 30°C, 60% RH), making it suitable for pools up to 50-60m² with proper ventilation.
Powerful Airflow System
900 m³/hr Air Volume – High-capacity dual fans circulate large volumes of air through the evaporator and condenser coils, ensuring rapid dehumidification and even air distribution.
Energy Efficient Operation
Low Running Costs – Advanced R407C refrigerant system with SEC (Specific Energy Consumption) of just 0.43 kWh/litre ensures cost-effective operation. The unit adds approximately 3.24kW of heat back into the space, reducing supplementary heating requirements.
Ultra-Quiet Performance
47-50 dB(A) at 1m – Operates at conversation-level noise (50dB wall-mounted, 47dB through-wall configuration), ensuring minimal disruption to pool users.
Professional Build Quality
- Epoxy-coated evaporator and condenser coils resist corrosion in chlorinated environments
- Powder-coated metal components provide long-lasting durability
- IPX4 protection rating for splash-proof operation
- R407C refrigerant (ozone-friendly, GWP 1774)
Intelligent Control System
- Digital humidity control adjustable from 40-99% RH (±2% hysteresis)
- Automatic defrost function monitors evaporator temperature for ice-free operation
- Service interval reminders ensure preventative maintenance
- LED status indicator for at-a-glance system monitoring
- USB port for data logging and software updates
Space-Saving Wall Mount Design
Compact Installation – Measures just 1495mm (W) × 770mm (H) × 326mm (D), the wall-mounted design saves valuable floor space while providing optimal air circulation placement.
📊 Complete Technical Specifications
Dehumidification Performance
| Specification | CDP70 Wall Mount | CDP70 Through-Wall |
|---|---|---|
| Dehumidification Capacity | 69 litres/day | 69 litres/day |
| Capacity per Hour | 2.8 litres/hour | 2.8 litres/hour |
| Air Volume | 900 m³/hr | 900 m³/hr |
| Heat Output (Dehumidifier) | 3.24 kW | 3.24 kW |
| Operating Temperature Range | 10-36°C | 10-36°C |
| Humidity Operating Range | 40-100% RH | 40-100% RH |
| Humidity Control Range | 40-99% RH adjustable | 40-99% RH adjustable |
Performance figures based on air at 30°C and 60% RH; pool water at 28°C
Electrical Specifications
| Specification | Value |
|---|---|
| Power Supply | 230V / 1-phase / 50Hz |
| Nominal Power Consumption | 1.8 kW |
| Maximum Current Draw | 8 Amps |
| Required Fuse Rating | 20 Amp (motor rated) |
| SEC (Specific Energy Consumption) | 0.43 kWh/litre @ 28°C 60% RH |
| Protection Class | IPX4 (splash-proof) |
Refrigeration System
| Specification | Value |
|---|---|
| Refrigerant Type | R407C (ozone friendly) |
| Refrigerant Charge | 1.2 kg |
| Global Warming Potential (GWP) | 1774 |
| Compressor Type | Scroll compressor with thermal protection |
| Defrost System | Intelligent automatic hot gas defrost |
Physical Dimensions & Installation
| Specification | Wall Mounted | Through-Wall (T) |
|---|---|---|
| Width | 1495 mm | 1483 mm |
| Height | 770 mm | 700 mm |
| Depth | 326 mm | 304 mm |
| Weight | 75.5 kg | 77.5 kg |
| Condensate Drain Connection | 3/4″ BSP | 3/4″ BSP |
| Minimum Clearance (Top/Bottom) | 225 mm each | 225 mm each |
| Wall Duct Opening | N/A | 1095mm × 395mm |
Acoustic Performance
| Configuration | Sound Pressure Level at 1m |
|---|---|
| Wall Mounted | 50 dB(A) |
| Through-Wall (T model) | 47 dB(A) |
For reference: 50dB is similar to quiet conversation level
Components & Build Quality
| Component | Specification |
|---|---|
| Air Filter | PPI 15 foam filter (washable) |
| Evaporator Coil | Epoxy-coated copper/aluminum |
| Condenser Coil | Epoxy-coated copper/aluminum |
| Fan Motors | Permanently lubricated, maintenance-free |
| Enclosure | Powder-coated steel panels |
| Control Panel | Digital display with membrane keypad |
| Wiring Ingress | Cable glands with PG restraints |
🏊 Room Size & Coverage Recommendations
The CDP70 is designed for medium to large commercial pool environments. Use these guidelines to determine suitability:
Pool Size Coverage
| Pool Water Surface Area | Recommended Model | Notes |
|---|---|---|
| Up to 35m² | CDP40 | Small pools, low humidity loads |
| 35-50m² | CDP50 | Medium pools, moderate use |
| 50-70m² | CDP70 | Large pools, high occupancy |
| 70m²+ | Multiple units or larger system | Contact for sizing |
Coverage estimates based on pool water temperature 28-30°C, air temperature 30-32°C, room height 3-4m, with reasonable air tightness
📥 Downloads & Documentation
Access comprehensive technical information and installation guides:
📄 CDP Service Manual (opens in new tab)
Complete 40-page service manual covering installation procedures, electrical connections, wiring diagrams, maintenance schedules, troubleshooting guides, and spare parts identification. Essential for installers and service technicians.
📄 CDP Dehumidifier Brochure (opens in new tab)
Product specifications overview for the entire CDP range including performance data, dimensions, optional accessories, and application guidelines. Includes comparison charts for CDP40, CDP50, and CDP70 models.
Pool Volume Considerations
The CDP70 is ideal for pools containing:
- 80-150m³ of water (typical commercial pools)
- Public pools with 20-30+ bathers daily
- Spa pools with high evaporation rates
⚠️ Important Sizing Factors:
- Bather load (more users = more moisture)
- Air tightness (doors/windows must remain closed)
- Supplementary heating systems
- Pool cover usage (reduces evaporation by 60-90%)
- Splash activity levels
⏱️ Performance Data & Running Costs
Moisture Extraction Time Estimates
How quickly will the CDP70 reduce humidity?
The table below shows estimated time to reduce relative humidity in different room volumes. These are theoretical calculations assuming:
- Starting humidity: 70% RH
- Target humidity: 50% RH
- Room temperature: 30°C
- Sealed room (no infiltration)
| Room Volume | Air Changes | Estimated Time to 50% RH |
|---|---|---|
| 200m³ (e.g., 50m² × 4m high) | 4.5 per hour | 2.5-3.5 hours |
| 300m³ (e.g., 75m² × 4m high) | 3.0 per hour | 4-5 hours |
| 400m³ (e.g., 100m² × 4m high) | 2.25 per hour | 5.5-7 hours |
⚠️ Disclaimer: These are theoretical estimates. Actual performance varies significantly based on:
- Initial moisture load in building materials
- External air infiltration rates
- Pool water temperature
- Number of occupants
- Ambient outdoor conditions
- Supplementary ventilation systems
Annual Running Cost Estimates
How much does it cost to run the CDP70?
Based on 1.8kW power consumption and typical UK electricity rates:
| Usage Pattern | Hours/Day | Days/Year | Annual kWh | Cost @ £0.25/kWh | Cost @ £0.35/kWh |
|---|---|---|---|---|---|
| Light Use (Hotel Spa) | 4 hours | 200 days | 1,440 kWh | £360 | £504 |
| Moderate Use (Gym Pool) | 8 hours | 300 days | 4,320 kWh | £1,080 | £1,512 |
| Heavy Use (Public Pool) | 12 hours | 350 days | 7,560 kWh | £1,890 | £2,646 |
💡 Energy Saving Tip: The CDP70 returns 3.24kW of heat to the room during operation. This recovered heat reduces supplementary heating requirements, offsetting 60-80% of dehumidifier running costs in most installations.
Cost Comparison vs. Alternative Methods
| Method | Typical Annual Cost | Energy Efficiency | Notes |
|---|---|---|---|
| CDP70 Dehumidifier | £1,000-£2,000 | ⭐⭐⭐⭐⭐ | Heat recovery offsets costs |
| Desiccant Dehumidifier | £2,500-£4,000 | ⭐⭐⭐ | Higher energy consumption |
| Ventilation Only | £1,500-£3,000 | ⭐⭐ | Heat loss, weather dependent |
| Over-Ventilation + Heating | £3,000-£6,000 | ⭐ | Significant heat waste |
✅ Best Value: Refrigerant dehumidifiers like the CDP70 offer the most cost-effective humidity control for indoor pools.
🔧 Installation Requirements
Wall Mounting Installation (Standard CDP70)
Minimum Clearances:
- ✅ Ceiling clearance: 225mm minimum
- ✅ Floor clearance: 225mm minimum
- ✅ Side clearances: 100mm recommended for maintenance access
- ✅ Front clearance: 500mm for filter access and servicing
What’s Included:
- Wall suspension bracket
- Wall mounting spacers (×2)
- Installation hardware
- Comprehensive installation manual
Required Accessories (Not Included):
- 3/4″ condensate drain hose/pipe
- Suitable wall fixings for building type
- Electrical supply cabling (2.5mm² minimum)
- 20A motor-rated fuse/MCB
Through-Wall Installation (CDP70T Model)
Additional Requirements:
- Wall opening: 1095mm (W) × 395mm (H)
- CDP-T wall duct kit (optional accessory – recommended for neat finish)
- Structural lintel if opening spans load-bearing wall
- Weatherproof external grille (if applicable)
Condensate Drainage
Critical Installation Notes:
- Connect 3/4″ flexible or rigid drain hose to unit outlet
- ⚠️ Minimum 2% fall required (20mm drop per meter of run)
- Drain must discharge to waste (foul drain, soakaway, or condensate pump)
- Average condensate production: Up to 69 litres per day (approx. 2.9 litres/hour)
If gravity drainage not possible:
- Install condensate pump at unit outlet
- Pump must handle 3+ litres/hour flow rate
- Check valve recommended to prevent backflow
Electrical Connection
⚠️ Must be installed by qualified electrician in accordance with current IET Wiring Regulations
Requirements:
- 230V single-phase supply
- 20 Amp Type B or C MCB (motor rated)
- 2.5mm² cable minimum (longer runs may require 4mm²)
- Earth connection mandatory
- RCD protection recommended (30mA)
Control Interfaces Available:
- USB port (software updates, data logging)
- Modbus RS485 (Building Management System integration)
- External humidity/temperature sensor terminals
- Run/Fail alarm relay outputs
- Heating coil control terminals (12V DC output)
🛠️ Optional Accessories & Upgrades
Enhance your CDP70 system with these factory-approved accessories:
Climate Control Options
💨 Low Pressure Hot Water (LPHW) Heating Coil
- Adds 7.56kW supplementary heating
- Total heat output: 9.3kW (combined with dehumidifier)
- Requires 10.2 L/min flow rate, 12mm connections
- Recommended boiler output: 7.56kW minimum
- Ideal for maintaining precise pool hall temperatures
⚡ Electric Heating Coil
- Adds 5kW electric heating
- Total heat output: 6.27kW (combined with dehumidifier)
- Additional power requirement: +5kW (27.2A total, requires 38A fuse)
- Simpler installation than LPHW (no plumbing required)
Control Valve for LPHW System
- Modulating control for precise temperature management
- Integrates with CDP70 digital controller
- Prevents overheating and reduces cycling
Installation & Configuration
📱 Wireless Remote Control DRC1
- Control humidity and temperature settings from anywhere in the room
- Wall-mounted display with backlit screen
- Range: up to 30 meters
- Battery-powered (no wiring required)
- Ideal for staff areas or reception desks
🏢 Floor Mounting Kit
- Convert wall-mount unit to floor-standing configuration
- Useful for spaces without suitable wall fixing points
- Includes anti-vibration feet
- Maintains optimal airflow patterns
🚪 Through-Wall Duct Kit
- Professional wall transition components
- Includes inlet/outlet grilles with filters
- Extension sections available for thicker walls
- Aluminum grilles (weather-resistant finish)
- Duct lead-in adapter for perfect fit
Filters & Maintenance
🔄 Replacement PPI 15 Foam Filter (Order Code: 094686)
- Washable and reusable
- Recommended replacement: annually or when damaged
- Easy tool-free installation
- Protects evaporator coil from dust and debris
🌡️ How It Works: The Condensation Principle
The Dantherm CDP70 operates using proven refrigeration technology to remove moisture from the air:
The Dehumidification Cycle
1. Air Intake 🌬️
Humid air from the pool room is drawn into the unit by powerful 900m³/hr fans through the washable foam pre-filter.
2. Cooling & Condensation ❄️
Air passes over the cold evaporator coil where it’s cooled below dew point. Water vapor condenses into liquid water which collects in the drip tray and drains away (up to 69 litres per day).
3. Reheating 🔥
Now-dry air passes through the hot condenser coil where it’s warmed by the heat from the refrigeration cycle plus compressor energy. Air exits approximately 5°C warmer than it entered.
4. Return to Room ♻️
Warm, dry air is returned to the pool space, simultaneously reducing humidity AND adding heat (3.24kW), which reduces supplementary heating requirements.
Intelligent Features
🧊 Automatic Defrost System The CDP70 continuously monitors evaporator temperature. When ice formation is detected:
- Fans stop automatically
- Solenoid valve opens to route hot gas through evaporator
- Ice melts quickly without manual intervention
- Normal operation resumes when coil temperature is optimal
🛡️ Safety Protection
- High-pressure cutout: Prevents compressor damage if airflow restricted
- Low-pressure monitoring: Detects refrigerant leaks early (LPCO pre-warning system)
- Thermal overload: Compressor shuts down if temperature exceeds 55°C
- Anti-short-cycle timer: Minimum 6 minutes between compressor starts (max 10 starts/hour)
📊 Intelligent Control
- Hourly humidity sampling: T-models check humidity once per hour when in standby
- Only runs when needed: Compressor and fans activate only when humidity exceeds setpoint
- Hysteresis control: ±2% RH prevents constant cycling
- Temperature compensation: Adjusts performance based on ambient temperature (10-36°C range)
💚 Environmental Performance & Water Quality
Chlorinated Pool Compatibility
The CDP70 is specifically engineered for harsh chlorinated pool environments. All wetted surfaces feature protective coatings:
✅ Epoxy-Coated Heat Exchangers
Evaporator and condenser coils have factory-applied epoxy coating resistant to chlorine vapor, chloramines, and other pool chemicals.
✅ Powder-Coated Metal Panels
All steel components are powder-coated BEFORE assembly, providing superior corrosion protection compared to post-assembly painting.
✅ Stainless Steel Fasteners
Critical fixings use corrosion-resistant materials for long service life.
Water Quality Requirements
To ensure warranty validity and optimal performance, maintain these water chemistry parameters:
For Pools with Chemical Addition:
| Parameter | Required Range |
|---|---|
| Free Chlorine | 1.0 – 2.0 ppm |
| Combined Chlorine | Max. 1/3 of free chlorine |
| pH | 7.2 – 7.6 |
| Total Alkalinity | 80 – 150 ppm |
| Calcium Hardness | 250 – 450 ppm |
| Total Dissolved Solids (TDS) | <2,000 ppm |
| Sulphates | <360 ppm |
For Salt Water Pools (Electrolytic Chlorine Generation):
| Parameter | Required Range |
|---|---|
| Salt (NaCl) | <30,000 ppm (3%) |
| Total Dissolved Solids (TDS) | <5,500 ppm |
| pH | 7.2 – 7.6 |
| Total Alkalinity | 80 – 150 ppm |
| Calcium Hardness | 250 – 450 ppm |
| Sulphates | <360 ppm |
⚠️ Important: Poor water chemistry will void warranty and can destroy the unit in weeks. Use the Langelier Saturation Index to verify balanced water chemistry. Contact Dantherm support if you need assistance calculating LSI.
Refrigerant Environmental Impact
R407C Refrigerant:
- Charge: 1.2 kg per unit
- Global Warming Potential (GWP): 1774
- Ozone Depletion Potential (ODP): Zero
- CO₂ Equivalent: 2.13 tonnes CO₂e over refrigerant lifetime
The CDP70 uses a moderate-GWP refrigerant that is more environmentally friendly than older R22 systems (GWP 1810) but not as low as newer R32 (GWP 675) or R290 (GWP 3) options. However, R407C offers excellent performance in pool dehumidification applications and complies with current F-Gas regulations.
End of Life: Units must be professionally decommissioned with refrigerant recovery by certified technicians. Compressor oil contains refrigerant and requires proper disposal per local regulations.
❓ Frequently Asked Questions
General Questions
Q: What size pool is the CDP70 suitable for?
A: The CDP70 is designed for pools with water surface areas of 50-70m² in typical conditions (water 28-30°C, air 30-32°C, moderate bather load). For pools at the upper end of this range or with heavy use, consider running the unit longer hours or adding supplementary dehumidification. Pools over 70m² may require multiple units or a larger capacity system.
Q: Can I use this in a domestic home pool?
A: While the CDP70 is marketed for commercial applications, it works excellently in large residential pools (8m × 4m and larger). However, the high extraction rate may be oversized for small domestic pools—consider the CDP40 or CDP50 for pools under 40m². The professional-grade construction ensures long service life even with daily residential use.
Q: What’s the difference between CDP70 and CDP70T models?
A: The CDP70 is a standard wall-mounted unit with front air intake and outlet. The CDP70T is a “through-wall” model where air is drawn from one room (e.g., adjacent plant room) and exhausted to the pool hall through the wall. The T-model is 3dB quieter (47dB vs. 50dB) because the noisy components sit outside the pool space. Both have identical dehumidification capacity.
Q: How much does the CDP70 weigh and can my wall support it?
A: The unit weighs 75.5-77.5kg including refrigerant. The wall bracket distributes this load across multiple fixing points. Most solid masonry, blockwork, and stud walls (properly reinforced) can support this weight. For lightweight partition walls, install a timber or steel spreader plate across multiple studs, or use the optional floor mounting kit. Consult a structural engineer if unsure.
Installation & Setup
Q: Can I install this myself or do I need a professional?
A: Electrical connection must be performed by a qualified electrician per IET Wiring Regulations. Mechanical installation (wall mounting, drainage) can be done by competent DIYers with good skills. However, professional installation is recommended to ensure correct refrigerant circuit integrity, optimal placement, and warranty compliance. Dantherm dealers offer installation services.
Q: What happens if I can’t provide gravity drainage?
A: Install a condensate pump at the unit’s 3/4″ drain outlet. The pump lifts water to an elevated drain point (loft drain, first-floor waste pipe, etc.). Choose a pump rated for at least 3 litres/hour continuous flow. Many HVAC condensate pumps work perfectly. Ensure the pump has a reservoir to handle intermittent high-flow periods.
Q: Do I need to buy the through-wall duct kit?
A: For CDP70T through-wall models, the duct kit is highly recommended but not mandatory. It provides neat inlet/outlet grilles, sealing sleeves, and filters for a professional appearance. Without it, you’ll need to fabricate your own wall penetration solution and source grilles separately. The duct kit saves time and ensures proper fit.
Q: Can I connect this to a Building Management System (BMS)?
A: Yes! The CDP70 features a Modbus RS485 interface for integration with commercial BMS systems. This allows remote monitoring of humidity levels, operating status, fault conditions, and control of setpoints. A full Modbus register map is available from Dantherm support for system integrators.
Q: How do I connect an external humidity sensor?
A: The CDP70 has dedicated terminals for an external RH/T (relative humidity & temperature) sensor. Simply connect the sensor to the appropriate terminals (refer to wiring diagram in manual), then use the DIP switch on the control board to select “external sensor mode.” This allows placement of the sensor in a more representative location away from the unit’s immediate vicinity.
Operation & Maintenance
Q: How often do I need to clean the filter?
A: The foam pre-filter should be cleaned monthly in most pool environments. In heavy-use facilities or where airborne debris is significant (outdoor dirt, leaves tracked in), inspect every 2 weeks. To clean: remove front cover, pull out filter, wash in warm soapy water, rinse thoroughly, allow to dry completely, then reinstall. Replace filter annually or when damaged (Order Code: 094686).
Q: How much noise does it make in operation?
A: The CDP70 operates at 50 dB(A) at 1 meter (wall-mounted) or 47 dB(A) (through-wall). For reference, 50dB is similar to:
- Normal conversation at 1 meter distance
- Quiet office environment
- Rainfall or rustling leaves
It’s quiet enough that conversations near the unit are not disrupted. Through-wall models are 3dB quieter (perceived as 20-25% quieter) because mechanical components are in an adjacent space.
Q: What maintenance does the unit require?
A: Monthly: Clean air filter
Annually: Vacuum evaporator and condenser coils, inspect condensate drain, check electrical connections, verify refrigerant charge (qualified technician), test all safety cutouts
The compressor and fan motors are permanently lubricated and require no servicing. The CDP70 has a service interval reminder function that displays “SEr” when annual maintenance is due. Set the interval (1-99 weeks) in the menu.
Q: Can I run it 24/7 continuously?
A: Yes, the CDP70 is designed for continuous duty operation common in commercial pools. The unit will cycle on/off automatically based on humidity levels. When humidity is below setpoint (typically 50-60% RH), the compressor and fans stop, saving energy. It automatically restarts when humidity rises. There’s a 6-minute minimum delay between compressor starts to protect the compressor from short-cycling damage.
Q: What happens during a power cut?
A: The CDP70 will shut down during power loss. When power is restored, it automatically resumes normal operation according to the last programmed settings. All settings are stored in non-volatile memory (backed by battery). If humidity has risen significantly during the outage, the unit will immediately start dehumidifying to restore setpoint.
Performance & Efficiency
Q: How much will it cost to run per year?
A: Based on 1.8kW power consumption, annual costs range from:
- Light use (4 hrs/day × 200 days): £360-£504/year
- Moderate use (8 hrs/day × 300 days): £1,080-£1,512/year
- Heavy use (12 hrs/day × 350 days): £1,890-£2,646/year
(Calculated at £0.25-£0.35/kWh electricity rates)
However, the unit returns 3.24kW of heat to the room, which significantly reduces supplementary heating costs. Net operating cost is typically 30-50% lower when heat recovery is accounted for.
Q: Will it heat my pool room sufficiently?
A: The CDP70 alone provides 3.24kW of space heating through recovered heat. This is sufficient to:
- Offset heat losses in moderately insulated rooms (U-value 0.30 W/m²K or better)
- Maintain room temperature 2-4°C above outdoor temperature
- Replace heat lost through evaporation
For poorly insulated buildings or very cold climates, add supplementary heating using optional LPHW coil (+7.56kW, total 9.3kW) or electric heating coil (+5kW, total 6.27kW). The CDP70 controller can manage these heating systems automatically.
Q: What’s the most energy-efficient way to run it?
A: Follow these best practices:
- Use a pool cover when pool not in use (reduces evaporation 60-90%)
- Set humidity to 55-60% RH (not lower—over-drying wastes energy)
- Set temperature to 28-30°C (higher temps increase evaporation)
- Keep doors and windows closed (infiltration ruins efficiency)
- Clean filter monthly (dirty filter reduces airflow, increases energy)
- Annual professional service (optimizes refrigerant charge and components)
- Run on off-peak electricity if possible (lower tariff rates)
Q: How long does it take to dry out a damp pool room?
A: This depends heavily on initial moisture load. For example:
- Newly plastered pool room: 4-8 weeks to dry out structural moisture
- After flooding/leak: 3-7 days to reach normal humidity levels
- Daily operation: Maintains 50-60% RH continuously
The unit can remove 69 litres per day, but building materials (concrete, plaster, grout) can hold 1000+ litres of moisture. Be patient during initial dry-out—this is normal. Once at equilibrium, the unit only removes water from pool evaporation (~10-30 litres/day for typical 50m² pools).
Troubleshooting & Support
Q: The LED is flashing red—what’s wrong?
A: Red LED indicates an alarm condition:
- Constant red + 3-second beep: High-pressure alarm (HP) – airflow restricted or condenser dirty
- Flashing red + double beep every minute: Low-pressure alarm (LP) – possible refrigerant leak
- Flashing red + single beep every 5 min: Sensor failure (SENS) – check sensor connections
Refer to the service manual troubleshooting section (pages 27-31) for detailed fault-finding procedures. If fault persists, contact Dantherm support or a qualified refrigeration engineer.
Q: Display shows “SEr”—what do I do?
A: This is the service interval reminder, not a fault. It indicates annual maintenance is due. Perform the maintenance tasks (clean coils, check drainage, inspect electrical, etc.), then reset the service interval in the menu:
- Press OK to enter menu
- Navigate to “SI” (Service Interval)
- Set to desired interval (1-99 weeks)
- Press OK to confirm
The “SEr” message will clear and the timer restarts.
Q: Condensate water isn’t draining—what should I check?
A: Common causes of drainage problems:
- Blocked drain pipe: Flush with water to clear debris
- Insufficient fall: Drain must have minimum 2% gradient (20mm/meter)
- Kinked flexible hose: Straighten or replace hose
- Frozen trap: In unheated spaces, insulate drain pipe
- Drip tray overflow: Clean drip tray and outlet spigot monthly
If water backs up into unit, shut down immediately to prevent electrical damage. Resolve drainage issue before restarting.
Q: The unit runs but humidity stays high—why?
A: Several possibilities:
- Doors/windows open: Infiltration overwhelms dehumidification capacity
- Undersized for application: Room/pool larger than 70m² requires more capacity
- High bather load: Many users add moisture faster than removal
- Dirty filter/coils: Restricts airflow, reduces performance by 30-50%
- Refrigerant leak: Requires professional service (check for LP/HP alarms)
- Setpoint too high: Lower humidity setpoint to 50% RH (not below 45%)
Check obvious issues first (doors, filter), then contact support if problem persists.
Q: Where can I get spare parts?
A: Spare parts are available through:
- Dantherm authorized dealers (UK-wide network)
- Certikin distributors (listed on their website)
- Direct from Dantherm support: support.dantherm.com or shop.dantherm.com
Common spare parts:
- Replacement filter (Code 094686)
- Sensors (evaporator, condenser, humidity/temperature)
- Fan motors and capacitors
- Solenoid defrost valve
- Control board PCB
- Compressor run capacitor
Major components (compressor, heat exchangers) are available but usually economical only for units within warranty period.
✅ What’s Included
Standard Package Contents
- ✅ Dantherm CDP70 wall-mounted dehumidifier unit (fully assembled and charged)
- ✅ Wall mounting bracket with suspension bar
- ✅ Wall mounting spacers (×2)
- ✅ PPI 15 washable foam air filter (pre-installed)
- ✅ Installation hardware kit
- ✅ Comprehensive installation and service manual
- ✅ User operation guide
- ✅ Warranty registration card
What’s NOT Included (Purchase Separately)
- ❌ Condensate drain hose/pipe (3/4″ BSP required)
- ❌ Electrical supply cabling and consumer unit connection
- ❌ Wall fixings (must be selected for your wall type)
- ❌ Through-wall duct kit (for T-models—highly recommended)
- ❌ Heating coils (LPHW or electric—optional accessories)
- ❌ Wireless remote control DRC1 (optional accessory)
- ❌ Floor mounting kit (optional accessory)
- ❌ Installation labor (unless purchased through dealer)
🏆 Warranty & Certification
Manufacturer Warranty
2-Year Comprehensive Warranty:
- Year 1: Parts AND labor fully covered
- Year 2: Parts only (labor costs apply)
Warranty covers manufacturing defects and component failures under normal use. Excludes:
- Improper installation
- Inadequate maintenance (e.g., filter not cleaned)
- Damage from poor water chemistry (outside specified parameters)
- Unauthorized modifications
- Normal wear items (filters, seals)
Register your unit within 30 days of installation at support.dantherm.com to activate warranty.
Quality Certifications
The Dantherm CDP70 complies with:
✅ European Directives:
- 2006/42/EC Machinery Directive
- 2014/30/EU EMC Directive (electromagnetic compatibility)
- 2011/65/EU RoHS Directive (hazardous substances restriction)
- 1907/2006/EC REACH Regulation (chemical safety)
✅ Harmonized Standards:
- EN 60335-1:2012 (Household appliances – General safety)
- EN 60335-2-40:2003 (Household appliances – Heat pumps)
- EN 378-1:2016 & EN 378-2:2016 (Refrigerating systems – Safety)
- DS/EN ISO 12100-2010 (Machinery safety – General principles)
✅ ISO 9001 Registered (Dantherm A/S manufacturing quality management)
✅ CE Marked (Conforms to European Economic Area requirements)
🇩🇰 About Dantherm
Dantherm A/S is a leading Danish manufacturer of climate control solutions with over 60 years of engineering excellence. Based in Skive, Denmark, Dantherm specializes in professional-grade dehumidification, heating, cooling, and ventilation systems for demanding applications.
Why Choose Dantherm?
- ✅ Danish engineering quality and precision
- ✅ Specifically designed for pool environments
- ✅ Extensive R&D with real-world testing
- ✅ UK-wide dealer and service network
- ✅ Comprehensive technical support
- ✅ Long production runs ensure parts availability
The CDP range represents decades of refinement based on feedback from thousands of commercial pool installations worldwide. When you choose Dantherm, you’re investing in proven reliability.
Before You Order, Measure:
- ✅ Pool water surface area (m²)
- ✅ Pool hall volume (length × width × height in meters)
- ✅ Available wall space (1495mm W × 770mm H minimum)
- ✅ Condensate drain route and fall
- ✅ Electrical supply location
- ✅ Typical pool water temperature
- ✅ Number of daily bathers (typical)
- ✅ Existing ventilation/heating systems
This information helps dealers confirm correct sizing and recommend appropriate accessories.
🌟 Summary: Why the CDP70 is the Smart Choice
The Dantherm CDP70 delivers professional-grade humidity control with impressive energy efficiency and whisper-quiet operation. With 69 litres daily capacity, it handles medium to large commercial pools while returning valuable heat to the space—reducing overall climate control costs by 30-50%.
Key Advantages: ✅ Proven Reliability – Danish engineering with 60+ years heritage
✅ Energy Efficient – Low 0.43 kWh/litre SEC rating
✅ Quiet Operation – Just 47-50 dB(A), won’t disturb pool users
✅ Corrosion Resistant – Epoxy-coated coils withstand harsh chlorine
✅ Intelligent Control – Automatic defrost, modbus integration, remote monitoring
✅ Heat Recovery – 3.24kW returned to space reduces heating bills
✅ Flexible Installation – Wall-mount or through-wall configurations
✅ Low Maintenance – Monthly filter cleaning, annual professional service
✅ Comprehensive Warranty – 2-year parts and labor (year 1)
Perfect for:
Commercial pools • Hotel spas • Health clubs • Therapy pools • Rehabilitation centers • Large residential pools
Order your Dantherm CDP70 today and experience the difference that professional-grade climate control makes. Your pool environment will be more comfortable, your energy bills lower, and your facility protected from moisture damage for years to come.