🎛️ Balboa AX10-A2 Auxiliary Control Panel – Remote Jets 2 Control for Larger Spas
💫 Single-button auxiliary panel for Jets 2 control from a secondary location – the current replacement for all AX10-A2 models
📋 Product Overview
The Balboa AX10-A2 Auxiliary Control Panel (TS-AX112) is the current production model for remote Jets 2 (second jet pump) control in larger hot tubs and spas. This compact single-button panel allows users to activate Jets 2 from a secondary location away from the main topside controls, providing convenient access to your second jet pump without needing to reach the main control panel.
Featuring a circular design with 54 mm diameter, the AX10-A2 fits into a standard 32 mm hole and comes with an impressive 5-metre cable length, allowing flexible installation at various positions around the spa. Operating at 12V, this panel connects via a 6-pin connector (2 rows of 3 pins) to the spa pack’s auxiliary port.
This model (TS-AX112) uses the current Balboa reference G8912 and replaces previous AX10-A2 topsides including part numbers 52764 and 52804. Please note that the overlay is not included with this model and must be purchased separately.
⭐ Key Features
- ✅ Current Production Model – Balboa reference G8912
- ✅ Jets 2 Control – Dedicated second jet pump activation
- ✅ 5-Metre Cable – Long reach for flexible positioning
- ✅ Compact Circular Design – 54 mm diameter
- ✅ Standard Hole Size – Fits 32 mm cutout
- ✅ Remote Installation – Control jets away from main topside
- ✅ 12V Operation – Safe low voltage design
- ✅ 6-Pin Connection – 2 rows of 3 pins connector
- ✅ Replaces Previous Models – Direct replacement for 52764, 52804
- ✅ Ideal for Multi-Pump Spas – Perfect for spas with 2+ jet pumps
⚠️ Important: Overlay NOT included – must be purchased separately.
🔧 Technical Specifications
| Specification | Value |
|---|---|
| Manufacturer | Balboa |
| Model | AX10-A2 |
| Model Series | AX |
| Product Type | Auxiliary Panel |
| SKU | TS-AX112 |
| Balboa Reference | G8912 |
| Replaces Part Numbers | 52764, 52804 |
| Number of Buttons | 1 |
| Button Function | Jets 2 |
| Cable Length | 5 m |
| Panel Diameter | 54 mm |
| Fits Hole Size | 32 mm |
| Operating Voltage | 12V |
| Connection Type | 6 Small Plastic Pins (2 Rows of 3) |
| Maximum Pumps Controlled | 1 |
| Blower/Auxiliary Outputs | 0 |
| Overlay Included | ❌ No – Sold Separately |
| Status | ✅ ACTIVE |
🔄 Replacement Information
This Model Replaces:
| Old Part Number | Old SKU | Status |
|---|---|---|
| 52764 | – | ⚠️ Discontinued |
| 52804 | – | ⚠️ Discontinued |
| AX10-A2 (with overlay) | TS-AX102 | ⚠️ Discontinued |
Current Model:
| New Balboa Ref | New SKU | Status |
|---|---|---|
| G8912 | TS-AX112 | ✅ ACTIVE |
If you have an existing AX10-A2 with part number 52764 or 52804, the TS-AX112 is the correct replacement. Remember to purchase an overlay separately if required.
🔘 Button Function
Single Button Operation:
| Button | Function |
|---|---|
| JETS 2 | Activate/deactivate jet pump 2 |
Operating Notes:
- Press once to activate Jets 2
- Press again to cycle through speed settings (if multi-speed pump)
- Press again to deactivate
- Behaviour depends on spa pack configuration
🔗 AX10 Series Comparison
Choosing Between AX10-A1 and AX10-A2:
| Model | SKU | Balboa Ref | Controls | Use Case |
|---|---|---|---|---|
| AX10-A1 | TS-AX111 | G8911 | Jets 1 | Primary jet pump remote |
| AX10-A2 | TS-AX112 | G8912 | Jets 2 | Second jet pump remote |
Both models share identical physical specifications – the only difference is which pump they control.
🎯 Purpose & Application
What is an Auxiliary Panel?
Unlike main topside control panels that provide full spa control (temperature, all pumps, lights, modes), auxiliary panels are secondary controls designed to operate specific functions from remote locations around the spa.
Why Use an AX10-A2?
| Scenario | Benefit |
|---|---|
| Large hot tubs with 2+ pumps | Control second pump from remote location |
| Swim spas | Activate Jets 2 from swimming area |
| Therapy zones | Dedicated control for therapy jets |
| Multi-zone spas | Independent control of different jet zones |
Typical Installation Locations:
- Near seating areas served by Pump 2
- Opposite end of spa from main topside
- Adjacent to therapy jet zones
- Secondary user positions in large spas
⚙️ Installation Guide
Before Installation:
- ⚠️ Disconnect power to spa at the isolator/breaker before any work
- ⚠️ Verify your spa pack has Jets 2 (second pump) configured
- ⚠️ Locate available 6-pin auxiliary port on PCB
- ⚠️ Plan cable routing (5 m available length)
- ⚠️ Prepare 32 mm hole at desired location
- ⚠️ Purchase overlay separately if required
Installation Steps:
- Turn off power at the isolator/breaker
- Drill or prepare 32 mm hole at desired auxiliary control location
- Route the 5 m cable from installation point to spa pack
- Connect the 6-pin connector to the spa pack’s auxiliary port
- Mount the AX10-A2 panel in the 32 mm hole
- Apply overlay (purchased separately)
- Secure panel and ensure watertight seal
- Restore power and test Jets 2 function
Mounting Information:
| Specification | Detail |
|---|---|
| Panel Diameter | 54 mm |
| Required Hole Size | 32 mm |
| Cable Length | 5 m |
| Connection | 6 small plastic pins (2 rows of 3) |
| Mounting Type | Push-fit into hole |
⚠️ Professional installation recommended for drilling into spa shell and ensuring watertight sealing.
⚡ Wiring & Connection
Connector Information:
| Specification | Detail |
|---|---|
| Connector Type | 6 Small Plastic Pins |
| Pin Configuration | 2 Rows of 3 Pins |
| Cable Length | 5 metres |
| Operating Voltage | 12V |
Connection Location:
The AX10-A2 connects to the auxiliary panel port on compatible Balboa spa packs. Refer to your spa pack documentation for the specific auxiliary port location.
⚠️ Never force the connector. The 6-pin auxiliary connector is different from the 8-pin main topside connector. Ensure you connect to the correct port.
🔍 Troubleshooting
Common Issues:
| Problem | Possible Cause | Solution |
|---|---|---|
| Button not responding | No power or loose connection | Check power and reseat 6-pin connector |
| Jets 2 don’t activate | Pump 2 not configured or faulty | Check pump 2 configuration and connections |
| Jets 1 activates instead | Connected to wrong auxiliary port | Check wiring corresponds to Jets 2 |
| Intermittent operation | Cable damage or poor connection | Inspect cable and connectors |
| Panel loose in hole | Incorrect hole size | Check 32 mm hole size |
Important Notes:
- The AX10-A2 only controls Jets 2 – it cannot control Jets 1 or other functions
- Ensure your spa pack has a second pump installed and configured
- If Jets 2 doesn’t work from the AX10-A2 but works from main topside, check auxiliary port connection
🧹 Maintenance & Care
Routine Care:
| Task | Frequency |
|---|---|
| Wipe with soft damp cloth | Weekly |
| Check button response | Monthly |
| Inspect cable condition | Annually |
| Check watertight seal | Annually |
| Check overlay condition | Annually |
DO NOT:
- ❌ Use abrasive cleaners
- ❌ Pull or stress the cable
- ❌ Submerge cable connections
- ❌ Force button operation
🎯 Ideal Applications
| Application | Suitability |
|---|---|
| ♨️ Spas with 2+ jet pumps | ✅ Ideal |
| ♨️ Large hot tubs (6+ person) | ✅ Ideal |
| 🏊 Swim spas with dual pumps | ✅ Ideal |
| ♨️ Therapy/hydrotherapy spas | ✅ Ideal |
| 🔄 Replacement for 52764, 52804, TS-AX102 | ✅ Direct replacement |
| ♨️ Single pump spas | ❌ Not applicable |
Common Replacement Scenarios:
- 💔 Non-responsive button
- 🔌 Damaged cable
- 💧 Water ingress damage
- 🔘 Worn panel (old 52764/52804 models)
❓ Frequently Asked Questions
Q: What is the difference between AX10-A1 (TS-AX111) and AX10-A2 (TS-AX112)?
A: The AX10-A1 controls Jets 1 (first jet pump) while the AX10-A2 controls Jets 2 (second jet pump). They are otherwise identical in specifications.
Q: I have an old AX10-A2 (52764 or 52804) – is this the correct replacement?
A: Yes, the TS-AX112 (Balboa reference G8912) is the current production model that replaces all previous AX10-A2 variants including part numbers 52764 and 52804.
Q: Is the overlay included?
A: No, the overlay is NOT included with the TS-AX112 and must be purchased separately. This differs from the older discontinued TS-AX102 which included the overlay.
Q: Can this panel control Jets 1 or other functions?
A: No, the AX10-A2 is specifically configured for Jets 2 control only. For Jets 1 remote control, you need the AX10-A1 (TS-AX111).
Q: Do I need a second pump for this to work?
A: Yes, the AX10-A2 controls Jets 2, which requires your spa to have a second jet pump installed and configured in the spa pack.
Q: What is the Balboa reference number?
A: The current Balboa reference for this model is G8912.
Q: What size hole do I need?
A: The AX10-A2 requires a 32 mm diameter hole. The panel itself is 54 mm in diameter (the flange that sits on top of the spa shell).
Q: Is the 5-metre cable long enough?
A: For most installations, 5 metres provides adequate reach from the auxiliary port to a remote location on the spa. Measure your specific requirement before ordering.
🏆 Why Choose the Balboa AX10-A2 (TS-AX112)
- ✅ Current Production Model – Balboa reference G8912
- ✅ Genuine Balboa Quality – Manufactured to Balboa’s standards
- ✅ Direct Replacement – For 52764, 52804, and TS-AX102
- ✅ Jets 2 Control – Dedicated second pump activation
- ✅ 5-Metre Cable – Generous length for flexible installation
- ✅ Compact Design – 54 mm diameter, fits 32 mm hole
- ✅ 12V Safety – Safe low voltage operation
- ✅ Currently Available – Active product in stock
🤝 Why Buy from Parts4Tubs
- ✅ UK-based company with local support
- ✅ Fast UK delivery
- ✅ Expert advice from spa specialists
- ✅ Auxiliary panel compatibility assistance
- ✅ Overlays available separately
- ✅ Full warranty support
- ✅ Easy returns within 30 days
Need an Overlay? The TS-AX112 does not include an overlay. Contact us for compatible overlay options.
Replacing an Old AX10-A2? If you have part number 52764 or 52804, the TS-AX112 is the correct current replacement.
Not Sure Which Auxiliary Panel You Need? Contact our team – we can help you choose between AX10-A1 (Jets 1) and AX10-A2 (Jets 2) based on your spa configuration.
✨ Summary
The Balboa AX10-A2 Auxiliary Control Panel (TS-AX112, Balboa reference G8912) is the current production model for remote Jets 2 control in larger hot tubs and swim spas with multiple pumps. This panel replaces previous models 52764, 52804, and TS-AX102. Featuring a compact 54 mm diameter circular design that fits a 32 mm hole, with 5-metre cable length and 12V operation via 6-pin connector (2 rows of 3). Overlay NOT included – purchase separately. Order from Parts4Tubs for fast UK delivery and expert support.