🔥 Bowman FC100-5114-2C Commercial Heat Exchanger | 100kW / 340,000 BTU | Cupro-Nickel
🌡️ High-Capacity Pool Heating from Britain’s Leading Heat Transfer Specialists – Engineered for Commercial and Large Residential Pools
📋 Product Overview
The Bowman FC100-5114-2C is a commercial-grade swimming pool heat exchanger delivering an impressive 100kW (340,000 BTU/hr) of heat transfer capacity when used with 82°C boiler water. Manufactured in Birmingham, UK, by EJ Bowman – a company with over 100 years of heat transfer expertise – this unit represents the perfect balance of power, durability, and efficiency for demanding pool heating applications.
Featuring Bowman’s advanced multi-tube design with more heat transfer tubes than most competitors, the FC100-5114-2C achieves rapid heat-up times whilst reducing energy consumption and operating costs. The Cupro-Nickel tubestack provides excellent corrosion resistance and heat transfer properties, making it ideal for standard chlorinated freshwater pools.
Designed for pools up to 170,000 litres (37,000 gallons), this heat exchanger integrates seamlessly with boilers, heat pumps, and solar thermal systems, making it ideal for commercial swimming centres, resort pools, large residential installations, and high-demand aquatic facilities.
⭐ Key Features
✅ Exceptional 100kW (340,000 BTU/hr) Heat Transfer – Rapid pool heating with 82°C boiler water supply
✅ Cupro-Nickel Tubestack – Excellent corrosion resistance and heat transfer for chlorinated freshwater pools
✅ Pools Up to 170,000 Litres (37,000 Gallons) – Sized for commercial and large residential applications
✅ Composite End Covers with Socket Unions – Professional-grade connections for easy installation and maintenance
✅ Integral 7mm Thermostat Pocket (52mm depth) – Built-in temperature monitoring capability on inlet end
✅ Counter-Flow Design – Maximises heat transfer efficiency between primary and secondary circuits
✅ Up to 3x Faster Heating Than Competitors – More tubes means greater surface area for heat exchange
✅ 6 Bar Maximum Operating Pressure – Robust construction for demanding commercial environments
✅ Compatible with Boilers, Heat Pumps & Solar Thermal – Versatile heat source integration
🔧 Technical Specifications
| Specification | Details |
|---|---|
| Model Number | FC100-5114-2C |
| Heat Output (82°C Boiler) | 100 kW / 340,000 BTU/hr |
| Heat Output (60°C Boiler) | 55 kW / 190,000 BTU/hr |
| Max Pool Volume | 170,000 litres / 37,000 gallons |
| Shell Material | Cast Iron Body |
| Tubestack Material | Cupro-Nickel |
| Boiler/Primary Flow Rate | 5.4 m³/h (90 L/min) |
| Pool/Secondary Flow Rate | 21.0 m³/h (350 L/min) |
| Max Operating Pressure | 6 bar (both sides) |
| Max Heating Water Temperature | 110°C |
| Max Pool Water Temperature | 100°C |
| Primary Connections (Boiler) | 1″ BSP Threaded |
| Secondary Connections (Pool) | Solvent Weld Ø60.3/Ø63mm (DN50) |
| Overall Length | 570 mm |
| Shell Diameter | 108 mm |
| Thermostat Pocket | Ø7 x 52 mm (inlet end) |
| Weight (Dry) | 8.8 kg |
| Warranty | 12 months |
All specifications from Bowman manufacturer documentation Issue F21/L21
📊 Heat Transfer Performance
The FC100-5114-2C delivers substantial heating capacity, with output varying based on your heat source temperature:
🏊 Pool Heating Capacity:
| Heat Source Temperature | Heat Output |
|---|---|
| 82°C (Standard Boiler) | 100 kW / 340,000 BTU/hr |
| 60°C (Condensing Boiler/Heat Pump) | 55 kW / 190,000 BTU/hr |
Performance figures based on achieving 30°C pool water temperature
⚡ Efficiency Factors:
- Flow rate optimisation – maintain recommended 90 L/min primary and 350 L/min secondary flow rates
- Temperature differential – greater difference between heat source and pool water improves efficiency
- Proper sizing – ensure heat source capacity matches heat exchanger rating
- Counter-flow installation – essential for maximum performance
⏱️ Heat-Up Times & Temperature Maintenance
⚠️ Heat-up times vary based on multiple factors including:
- Heat source output (boiler/heat pump kW rating)
- Starting water temperature
- Target water temperature
- Pool cover usage and insulation
- Ambient/outdoor temperature
- Weather conditions and heat losses
The Bowman FC100-5114-2C can transfer up to 100kW of heat energy when properly matched with an adequate heat source. Actual heating duration depends entirely on your specific installation configuration.
ℹ️ Note: Heat exchangers are passive devices that transfer heat from your boiler or heat pump to pool water. The heating time is determined by your heat source capacity, not the heat exchanger alone. For accurate calculations tailored to your installation, please contact our technical team.
🛡️ Material & Compatibility Guide
The FC100-5114-2C features a Cupro-Nickel tubestack, providing excellent performance for standard pool applications:
Cupro-Nickel Benefits
✅ Standard chlorinated freshwater pools
✅ Excellent heat transfer properties
✅ Good corrosion resistance for conventional pool chemicals
✅ Cost-effective for standard installations
✅ Proven durability in thousands of installations worldwide
Important Compatibility Notes
❌ Not suitable for salt water chlorinators
❌ Not suitable for salt water pools
For salt water applications, the Titanium variant (FC100-5114-2T) is required.
Recommended Water Chemistry Limits (from Bowman documentation):
| Parameter | Cupro-Nickel Limit |
|---|---|
| Free Chlorine | 1.0 – 3.0 ppm |
| pH | 7.2 – 7.8 |
| Calcium Hardness | 200 – 400 ppm |
| Alkalinity | 100 – 150 ppm |
| Bromine | 2.0 – 4.0 ppm |
| Chloride | Less than 150 ppm |
🎯 Applications & Use Cases
The FC100-5114-2C is engineered for demanding commercial and large residential applications:
🏢 Commercial Swimming Centres – High-capacity heating for public pools with continuous use demands
🏊♂️ Resort & Hotel Pools – Reliable performance for guest-facing facilities requiring consistent temperatures
🏠 Large Residential Pools – Suitable for pools up to 170,000 litres with high-output heating systems
🔥 Boiler Integration – Compatible with oil, gas, LPG, and biomass boilers delivering 82°C flow temperature
♨️ Heat Pump Systems – Optimised for lower temperature sources at 60°C with 55kW output
☀️ Solar Thermal Integration – Works with solar thermal panels in hybrid heating configurations
🔨 Installation Considerations
Mounting Options:
- Horizontal or vertical mounting permitted
- Install in frost-free, dry location with non-aggressive atmosphere
- Ensure adequate access for maintenance and tubestack removal
Connection Requirements:
- Primary (boiler) side: 1″ BSP threaded connections
- Secondary (pool) side: Solvent weld for Ø60.3mm (2″ imperial) or Ø63mm (DN50 metric) pipe
- Adaptors included to accommodate both imperial and metric pipework
Critical Installation Points:
- Counter-flow installation essential – pool water must flow opposite to heating water direction
- Install downstream of filtration equipment
- Chemical dosing systems must be fitted downstream of heat exchanger with non-return valve
- Use isolation valves on all connections for maintenance access
- Heating circuit should be pump-assisted with air lock prevention measures
- Install thermostat in pool water pipe before heat exchanger for temperature control
Operating Limits:
- Maximum pressure: 6 bar on both circuits
- Maximum heating water temperature: 110°C
- Maximum pool water temperature: 100°C
- Do not exceed 350 L/min pool water flow rate
⚠️ Professional installation is recommended for warranty compliance and optimal performance. Installation must comply with the Bowman Installation, Operation & Maintenance Guide.
📥 Downloads & Resources
Swimming Pool Heat Exchanger Brochure – Complete product range specifications and performance data (PDF)
Installation, Operation & Maintenance Guide – Full technical installation instructions and maintenance procedures (PDF)
🏆 Why Choose Bowman Heat Exchangers
✅ 100+ Years of British Manufacturing Excellence – EJ Bowman (Birmingham) Ltd has been pioneering heat transfer technology since 1921
✅ Industry-Leading Performance – More heat transfer tubes than competitors for up to 3x faster heating
✅ Global Track Record – Tens of thousands of units operating reliably worldwide, from domestic spas to Olympic pools
✅ Premium Cupro-Nickel Construction – Proven durability and excellent heat transfer properties
✅ Easy Maintenance – Removable tubestack and end covers for straightforward cleaning and servicing
✅ Proven Reliability – Trusted by prestigious installations including the Russian Spa Resort of Sochi (Winter Olympics 2014 venue) and Nirvana Spa UK
🛍️ Why Buy from Parts4Tubs
✅ UK-Based Pool & Spa Specialists – Expert knowledge of swimming pool heating systems
✅ Competitive Pricing – Trade and retail pricing on genuine Bowman heat exchangers
✅ Technical Support – Sizing advice and installation guidance from our experienced team
✅ Fast UK Delivery – Quick dispatch on stock items
✅ Genuine Bowman Parts – Authorised stockist of authentic Bowman products and spare parts
✅ After-Sales Support – Ongoing assistance with your installation and maintenance needs
✨ Summary
The Bowman FC100-5114-2C delivers commercial-grade pool heating performance with 100kW of heat transfer capacity, making it the ideal choice for large residential and commercial chlorinated freshwater pools up to 170,000 litres. The Cupro-Nickel tubestack provides excellent durability and heat transfer efficiency at a cost-effective price point. Backed by over a century of Bowman engineering expertise and British manufacturing quality, the FC100-5114-2C represents a reliable, long-term investment in your pool heating infrastructure.